Skip to content

RetroBridge on Linux

RetroBridge on Linux offers Modbus TCP, Emerson ROC Plus, and DNP3. OPC Classic DA is not available on Linux: the DA protocol is built on COM, a Windows technology, and the console does not offer the DA connector on a Linux node.

Supported platform

  • Linux on x86-64.
  • The node is a single native binary, the same platform code as a Flowgate node. No .NET, Java, or container runtime is required on Linux.
  • It uses the same TLS libraries as Flowgate on Linux (Mbed TLS cryptography and X.509).
  • There is no packaged Linux installer yet; installation is currently manual, done together with H2 Innovations, and the service is run under the service manager you configure.

Network

Port Direction Purpose
17080 Inbound The node's OPC UA endpoint. Deliberately different from Flowgate's 17070 so both products can share one machine.
8080 (or as configured) Inbound Web management console, HTTPS. When RetroBridge shares a machine with a Flowgate node, configure a different port, for example 8081.
17071 Outbound Optional uplink to a parent Flowgate node's Reverse Connect listener.
Device ports Outbound Modbus TCP, ROC Plus, and DNP3 connections dial the address and port you configure per device; these protocols have no fixed default port in RetroBridge.

Storage

Set the node's PKI directory explicitly in the configuration file; the node provisions its own identity there on first run and keeps its state and log files in sibling folders of that directory, the same layout as a Flowgate node.

Hardware

No formal minimum specification has been published yet.